HPLC Column, Zx Similars C18, 3um, 2.1mm ID x 50mm Length. Cogent Brand. 1 EA.
Additional Information:
Zx Similars C18™ is a traditional reversed-phase HPLC stationary phase manufactured on high-purity Type-B spherical silica with a fully endcapped octadecyl (C18) bonded phase. Designed as a cost-effective alternative to Agilent Zorbax® C18 columns, it offers comparable chromatographic behavior for USP L1 methods while providing the strong hydrophobic retention, reproducibility, and broad applicability expected from a conventional C18 stationary phase.
65318-05P-2 is a 50 mm x 2.1 mm ID narrow-bore analytical column packed with 3 µm Zx Similars C18 particles. The short 50 mm length is optimized for rapid analyses and reduced solvent consumption, while the 2.1 mm ID format is particularly well suited for LC-MS applications. The 3 µm particle size delivers significantly higher efficiency and improved peak capacity than traditional 5 µm columns, although it generates increased operating pressure. Typical operating flow rates are approximately 0.2–0.3 mL/min and require an HPLC or LC-MS system capable of reliable low-flow operation with low-volume plumbing and flow cells.
This USP L1 column is ideal for hydrophobic and neutral compounds requiring strong reversed-phase retention. Its narrow-bore design, low-flow operation, and fast analysis capability make it a popular choice for LC-MS methods, pharmaceutical analysis, long-chain fatty acid separations, and high-sensitivity analytical workflows requiring chromatographic behavior similar to Agilent Zorbax® C18 columns.
Key Benefits
Type-B spherical silica stationary phase
Suitable alternative for USP L1 methods
Comparable selectivity to Agilent Zorbax® C18 columns
Narrow-bore format ideal for LC-MS applications
Fast analysis with 50 mm column length
Higher efficiency than comparable 5 µm columns
Reduced solvent consumption
End-capped C18 bonded phase
Typical Applications
USP L1 methods
LC-MS analysis
Reversed-phase HPLC
Pharmaceutical analysis
Long-chain fatty acid analysis
Quality control testing
Fast analytical separations
Method transfer and validation
Specifications
Product Type: HPLC Column
Stationary Phase: Zx Similars C18
USP Classification: L1
Particle Size: 3 µm
Particle Type: Type-B Spherical Silica
Bonded Phase: C18 (Octadecyl)
Endcapped: Yes
Column Dimensions: 2.1 mm ID x 50 mm
Length: 50 mm
Recommended Flow Rate: 0.2–0.3 mL/min
Brand: Cogent
Important Notes
Designed for reversed-phase chromatography
Narrow-bore format optimized for LC-MS applications
Requires an HPLC or LC-MS system capable of reliable low-flow operation
Higher efficiency than comparable 5 µm columns
Increased operating pressure compared to larger particle sizes
Reduced solvent consumption compared to 4.6 mm ID columns
Excellent alternative for many USP L1 methods
Ideal for high-throughput LC-MS workflows